-40%

Proguard Protex Radiation Attenuation Surgical Gloves - CLEARANCE (EXP. 11-2022)

$ 71.28

Availability: 48 in stock
  • Size: 6
  • Brand: ProGuard
  • Condition: New
  • Intended Use/Discipline: Anesthesiology, Cardiology, General Surgery, Neurology, Orthopedics, Plastic Surgery, Radiology, Thoracic Surgery, Urology, Veterinary Medicine
  • Model: PX1

    Description

    Made from
    high quality lead plus latex-free elements
    , the Proguard Protex glove achieves greater protection with thinner and more tactile fingertips than the competition. This translates to improved dexterity and comfort while reducing hand fatigue. The glove interior features a superior slip-coat technology for hassle-free donning.
    The Protex's light tactile sensitivity and premium quality protection make it the preferred choice for doctors in the following vocations: Radiology, Cath/EP Lab, Orthopedics, Endoscopy, Urological Procedures, Special Procedures, and Pain Management.
    Protex is the same glove as the Proguard RR glove, but branded for Europe and CE.
    PACKAGING: 1 BOX (5 Pairs)  -
    ON CLEARANCE BECAUSE OF EXPIRY DATE NOVEMBER 2022 - NO RETURNS
    GLOVE CHARACTERISTICS
    Model:
    PX
    Material:
    Dry Natural Rubber and Lead Oxide (PbO)
    Color:
    Warm Gray
    Glove Design:
    Hand Specific
    Cuff:
    Non-beaded
    Internal Slipcoat:
    Polymer Coated
    Shelf Life:
    3 Years as per ASTM 7160-05
    Post Processing:
    Polymer Rinsing
    Glove Length:
    280mm (minimum)
    Sterility:
    Sterilized by Ethylene Oxide
    MODEL
    LEAD EQUIVALENCE
    THICKNESS
    60kVp
    80kVp
    100kVp
    120kVp
    Proguard PX1
    0.05mm Pb @ 60kVp
    +/- 0.24mm
    50%
    42%
    37%
    33%
    Proguard PX2
    0.07mm Pb @ 60kVp
    +/- 0.28mm
    58%
    50%
    45%
    41%
    Proguard PX3
    0.09mm Pb @ 60kVp
    +/- 0.38mm
    73%
    65%
    57%
    52%
    GLOVE COMPLIANCE
    Compliance Requirements:
    ASTM D5151, ASTM D6124, ASTM D412, ASTM F2547, EN ISO 374-1:2016, EN ISO 374-5:2016, EN 421:2010 (excl. clause 4.3) EN 420:2003 + A1:2009
    Biocompatibility Compliance:
    ISO 10993, ASTM F 719 and ASTM F 720
    STORAGE, DISPOSAL, AND EXPIRATION
    Store gloves in a cool, dry and ozone-free place. Keep out of direct sunlight.
    The Proguard RR glove contains lead and should be disposed of through hazardous waste procedures in accordance with local laws and regulations. The material should not be disposed of by incineration and use of self-contained breathing apparatus is recommended if the sheeting is ignited by fire.
    If sterilized, product expiration is set at 3 years from manufactured date per FDA requirement.
    PACKAGING
    Pouch:
    1 Pair
    Box:
    5 Pairs